Vista de pagina 0
1
ADDS REMOTE I/O CAPABILITY TO THE MODULAR
CONTROLLER SERIES
EIGHT INPUT, SIX OUTPUT DIGITAL MODULE
INPUTS ISOLATED FROM OUTPUTS
INPUTS INDEPENDENTLY SWITCH SELECTABLE FOR SINK OR
SOURCE SIGNALS
INPUTS INDEPENDENTLY CONFIGURABLE FOR HIGH OR LOW
ACTIVE STATE
INPUTS INDEPENDENTLY SWITCH SELECTABLE FOR HIGH OR
LOW FREQUENCY SIGNALS
RELAY OR NFET OUTPUT MODELS AVAILABLE
GENERAL DESCRIPTION
The Model CSDIO series modules are digital I/O modules designed for use
with the Modular Controller Series. The CSDIO14 offers eight inputs and six
outputs that can be used to monitor contact or sensor inputs and actuate relays,
solenoids, PLC inputs, etc.
The inputs accept standard DC inputs or contact closures, and are configured
for Sink/Source signals via external switches. Additionally, each input has a
switch selectable input filter that can be used to prevent contact bounce. Each
input may also be software configured as a high-active or low-active input.
The modules are available with relay or NFET outputs that are capable of
switching up to one amp each (NFET DC only). For applications requiring large
loads to be controlled, several DIN rail mount relays are available.
The CSDIO modules connect and communicate via a backplane connection
to the CSMSTR Modular Controller Series Master. The CSMSTR, equipped
with serial ports as well as an Ethernet port, allows the system to share data with
PCs, PLCs, and SCADA systems. The Master supports any combination of up
to 16 CS Series modules.
Internal power management circuits allow the modules to be replaced while
power is applied, which reduces downtime in the event of a relay failure. All
configuration information is stored locally within each module, as well as in the
Master, so replacement modules do not need to be configured. The Modular
Controller Series’ high density packaging and DIN rail mounting saves time and
panel space. The backplane connection provides power and communication to
the module and snaps easily onto standard top hat (T) profile DIN rail.
CONFIGURATION
The Modular Controller Series is configured with Windows
®
compatible
Crimson
®
software. The software is an easy to use, graphical interface that
provides a means of communication configuration, as well as commissioning
and calibration of new systems.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use the module to directly command motors, valves, or other actuators
not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the module.
MODEL CSDIO - MODULAR CONTROLLER
SERIES DIGITAL MODULE
Bulletin No. CSDIO-H
Drawing No. LP0558
Released 05/11
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
1
7
13
1.24
(126.5)
4.17 (105.9)
4.98
(31.5)
DIMENSIONS In inches (mm)
C
C
US LISTED
US LISTED
U
L
R
IND. CONT. EQ.
34AD
For Model No. CSDIO14S Only
FOR USE IN HAZARDOUS LOCATIONS:
Class I, Division 2, Groups A, B, C, and D
C
C
US
US
U
L
R
LISTED
IND.CONT. EQ.
3PWL
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I,
DIVISION 2, GROUPS A, B, C, D, OR NON-HAZARDOUS
LOCATIONS ONLY
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - SERIES DIGITAL MODULE

1 ADDS REMOTE I/O CAPABILITY TO THE MODULAR CONTROLLER SERIES EIGHT INPUT, SIX OUTPUT DIGITAL MODULE INPUTS ISOLATED FROM OUTPUTS INPUTS INDEP

Pagina 2 - CSDIO14R

2GENERAL SPECIFICATIONS1. POWER: Derived from system backplane. (CSDIO draws 170 mA max. load on power input of MASTER). Modules may be hot-swapped (r

Pagina 3 - EMC INSTALLATION GUIDELINES

3EMC INSTALLATION GUIDELINESAlthough Red Lion Controls Products are designed with a high degree of immunity to Electromagnetic Interference (EMI), pro

Pagina 4 - HARDWARE INSTALLATION

WIRINGWIRING CONNECTIONSAll conductors should meet voltage and current ratings for each terminal. Also, cabling should conform to appropriate standard

Pagina 5 - Error States

LEDSSTS – STATUS LEDThe Status LED is a dual color LED that provides information regarding the state of the module. This includes indication of the va

Pagina 6

6This page intentionally left blank

Pagina 7

7This page intentionally left blank

Pagina 8 - LIMITED WARRANTY

LIMITED WARRANTYThe Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from

Comentarios a estos manuales

Sin comentarios