GENERAL DESCRIPTION
The PAXLA is a versatile meter available as a DC volt, current, or process
meter with scaling and dual Form C relay outputs. The meter is programmed
through the front panel buttons and the use of jumpers. The RST Key will also
function as a front panel display reset.
Once the front panel programming is complete, the buttons can be disabled
by a user input setting. The meter has been specifically designed for harsh
industrial environments. With a NEMA 4X/IP65 sealed bezel and extensive
testing to meet CE requirements, the meter provides a tough yet reliable
application solution.
SAFETY SUMMARY
All safety regulations, local codes and instructions that appear in this and
corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected to
it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
ORDERING INFORMATION
MODEL NO. DESCRIPTION PART NUMBER
PAXLA
Volt/Current/Process Meter with Dual Relay Output PAXLA000
UL Listed Volt/Current/Process Meter with Dual
Relay Output
PAXLA0U0
PAXLBK Unit Label Kit Accessory PAXLBK10
SPECIFICATIONS
1. DISPLAY: 5 digit, 0.56" (14.2 mm) intensity adjustable Red LED (-19999 to
99999)
2. POWER REQUIREMENTS:
AC POWER: 50 to 250 VAC 50/60 Hz, 12 VA
Isolation: 2300 Vrms for 1 min. to all inputs and outputs
DC POWER: 21.6 to 250 VDC, 6 W
DC Out: +24 VDC @ 100 mA if input voltage is greater than 50 VAC/VDC
+24 VDC @ 50 mA if input voltage is less than 50 VDC
3. INPUT RANGES: Jumper Selectable
D.C. Voltages: 200 mV, 2 V, 20 V, 200 V, 10 V
INPUT
RANGE
ACCURACY @
23 °C LESS
THAN 85% RH
INPUT
IMPEDANCE
MAX
INPUT
SIGNAL
RESOLUTION
TEMP.
COEFFICIENT
200 mV 0.1% of span
1.033 M
75 VDC 10 µV 70 ppm /°C
2 V 0.1% of span
1.033 M
75 VDC 0.1 mV 70 ppm /°C
10 V 0.1% of span
1.033 M
250 VDC 1 mV 70 ppm /°C
20 V 0.1% of span
1.033 M
250 VDC 1 mV 70 ppm /°C
200 V 0.1% of span
1.033 M
250 VDC 10 mV 70 ppm /°C
D.C. Currents: 200 µA, 2 mA, 20 mA, 200 mA
INPUT
RANGE
ACCURACY @
23 °C LESS
THAN 85% RH
INPUT
IMPEDANCE
MAX
INPUT
SIGNAL
RESOLUTION
TEMP.
COEFFICIENT
200 µΑ 0.1% of span
1.111 K
15 mA 10 nA 70 ppm /°C
2 mA 0.1% of span
111
50 mA 0.1 µA 70 ppm /°C
20 mA 0.1% of span
11
150 mA 1 µA 70 ppm /°C
200 mA 0.1% of span
1
500 mA 10 µA 70 ppm /°C
D.C. Process: 4 to 20 mA, 1 to 5 VDC, 0/1 to 10 VDC
INPUT RANGE SELECT RANGE
4 - 20 mA Use the 20 mA range
1 - 5 VDC Use the 10V range
1 - 10 VDC Use the 10V range
5 DIGIT, 0.56" HIGH RED LED DISPLAY
PROGRAMMABLE SCALING AND DECIMAL POINTS
PROGRAMMABLE USER INPUT
DUAL 5 AMP FORM C RELAY
UNIVERSALLY POWERED
NEMA 4X/IP65 SEALED FRONT BEZEL
OPTIONAL CUSTOM UNIT OVERLAY W/ BACKLIGHT
MINIMUM AND MAXIMUM DISPLAY CAPTURE
MODEL PAXLA - PAX LITE DC VOLT/CURRENT/PROCESS METER
DIMENSIONS In inches (mm)
Bulletin No. PAXLA-D
Drawing No. LP0722
Released 04/14
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
C
US LISTED
U
L
R
51EB
IND. CONT. EQ.
For Model No. PAXLA0U0 Only
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - 8.8.8.8.8

13.60 (91.4)(96.5)3.801.95(49.5)(2.5).10(104.1)4.10(44.5)1.75PAR913245678101311121415SEL RSTPS1PS28.8.8.8.8XMAIMNVGENERAL DESCRIPTIONThe PAXLA is a ve

Pagina 2 - 1.0 InstallIng the Meter

100.0tOF-nOFF TIME DELAY0.0 to 599.9 SecEnter the time value in seconds that the output is delayed from turning off after the trigger point is reach

Pagina 3 - 2.0 settIng the JuMpers

11Filter BandInput RangeDisplay Decimal PointFilter SettingUser Input FunctionInput Value for Scaling Point 1User Input AssignmentPARSELExit Programmi

Pagina 4 - 3.1 POWER WIRING

LIMITED WARRANTYThe Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from

Pagina 5

24. OVERRANGE/UNDERRANGE INDICATION:Input Overrange Indication: “OLOL”.Input Underrange Indication: “ULUL”.Display Overrange/Underrange Indication:

Pagina 6 - A value of

33.0 WIrIng the MeterEMC INSTALLATION GUIDELINESAlthough Red Lion Controls Products are designed with a high degree of immunity to Electromagnetic Int

Pagina 7

43.2 USER INPUT WIRINGCAUTION: Analog common is NOT isolated from user input common. In order to preserve the safety of the meter application, the An

Pagina 8

4.0 revIeWIng the Front Buttons and dIsplay8.8.8.8.8AMXNMIRSTSELPARVSP1SP2DisplayReadoutLegends*Setpoint AlarmAnnunciatorsOptional CustomUnits Overlay

Pagina 9

6100.00dSP 2DISPLAY VALUE FOR SCALING POINT 2-19999 to 99999Enter the second Display Value by using the front panel buttons. This is the same for KE

Pagina 10 - LAtCHAuto L-dLY

7USER INPUT ASSIGNMENTSelect the value(s) to which the User Input Function is assigned. The User Input Assignment only applies if a selection of reset

Pagina 11 - Programming Mode

85.3 Module 3 - dIsplay and Front panel Button paraMeters (3-dSP)PARFront Panel Display Select EnableDisplay Update TimeFront Pan

Pagina 12 - LIMITED WARRANTY

9The Security Code determines the programming mode and the accessibility of programming parameters. This code can be used along with the Program Mode

Comentarios a estos manuales

Sin comentarios